HIOKI Digital Multimeters DT4281 And DT4282 Effectively Completed Professional Testing High Precision And High-speed Response

Brand Name : HIOKI

Model Number : HIOKI Digital multimeters DT4281 and DT4282

Certification : CO

Place of Origin : Japan

MOQ : 1

Price : 528-950USD

Payment Terms : T/T

Supply Ability : 99pcs/6-8weeks

Delivery Time : 6-8weeks

Packaging Details : Standard cardboard box packaging

Powersupply : 24 V DC

Mountingtype : Panel, Wall, Pipe

Protectionrating : IP65

Mounting : Panel mount or pipe mount

Outputsignal : 4-20 mA, 0-10 V

Displaytype : Digital LCD

Applications : Industrial, Automotive, HVAC, Oil & Gas

Measurementtype : Gauge, Absolute, Differential

Responsetime : ≤ 1 ms

Accuracy : ±0.25% FS

Ingressprotection : IP65, IP67

Calibration : Factory calibrated

Application : Industrial, HVAC, Automotive

Connectiontype : 1/4 inch NPT

Operatingtemperature : -20°C to 85°C

Contact Now

  • 5-bit display with 60,000 points, high-resolution measurement
  • DC V basic accuracy ±0.025%, AC V frequency characteristic is a wide frequency range of 20~100kHz
  • Low-pass filtering function removes harmonics (measurement of fundamental components in frequency converters)
  • Supports DC+AC measurement, temperature measurement, C measurement, frequency measurement, and other multifunctional functions
  • Terminal protection design to prevent accidents (to prevent test wires from being inserted by mistake)
  • High current measurement with current clamps (DT4281 only, no 10A port to prevent accidents),
  • Direct input measurement up to 10A (DT4282 only)
  • Voltage and frequency can be displayed simultaneously
  • Magnetic sling (optional)
  • Rear test cable storage
  • Backlight display, red backlight input alarm
  • 1-meter drop protection
  • USB communication function for PC measurement (optional)
  • Wide operating temperature range: -15°C~55°C
Basic parameters
DT4281 DT4282
DC voltage 60.000 mV~1000.0 V, 6 ranges, basic accuracy: ±0.025% rdg. ±2 dgt.
AC voltage:
45~66Hz
60.000 mV~1000.0 V, 6 ranges, frequency response: 20 Hz~100 kHz
Basic accuracy: ±0.3% rdg. ± 25 dgt. (RMS value, crest factor below 3)
DC + AC voltage:
45~66Hz
6. 0000 V~1000.0 V, 4 ranges, frequency response: 20 Hz~100 kHz
Basic accuracy: ±0.4% rdg. ±30 dgt. (RMS value, crest factor below 3)
Resistance 60.000 Ω~600.0 MΩ, 8 range ranges, [600.00 nS, DT4282 only]
Basic accuracy: ±0.03% rdg. ±2 dgt.
Direct current 600.00 μA~600.00 mA, 4 ranges 600.00 μA~10.000 A, 6 ranges
Basic accuracy: ±0.05% rdg. ±5 dgt.
AC current:
45~66Hz
600.00 μA~600.00 mA, 4 ranges 600.00 μA~10.000 A, 6 ranges
Basic accuracy: ±0.6% rdg. ±5 dgt. (RMS value, crest factor below 3)
Frequency Response: 20 Hz~20 kHz (at 600 μA~600 mA range)
AC current
(measured by AC clamp probe)
40~1kHz
10.00 A~1000 A, 7 range ranges None
Basic accuracy: ±0.6% rdg. ±2 dgt. Plus the clamp
probe for testing accuracy (RMS value, crest factor below 3)
None
Peak measurement DC V measurement: signal width above 4ms (single pass), over 1ms (repeated)
AC V, DC/AC A measurement, etc.: signal width over 1ms (single pass), 250μs or more (repeated)
Capacitive coupling 1.000 nF~100.0 mF, 9 ranges, basic accuracy: ± 1.0% rdg. ±5 dgt.
Continuity check Conduction ON threshold: 20~500 Ω and below
; Conduction OFF threshold: 220~600 Ω or below; response time: over 5ms
Diode testing Open-circuit voltage: below 4.5V, test current: below 1.2mA, clockwise threshold: 0.15~3V, 7 types
Frequency AC V, DC+AC V, AC A measurement, pulse width above 1μs (duty cycle 50%)
99.999 Hz (above 0.5 Hz) ~ 500.00 kHz, 5 ranges, ± 0.02% rdg. ±3 dgt.
Decibel conversion measurement Standard impedance setting (dBm), 4 Ω~1200 Ω, 20 types.
Displays the dB conversion value (dBV) of the standard value relative to AC voltage
Other features Filtering function (removal of harmonic interference, limited to AC600V/1000V range), display value hold,
auto hold, associated display, maximum/minimum value display, measurement value storage, USB communication (optional),
percentage conversion display (4-20mA/0-20mA converted to 0~100%), backlight
Display 5-digit LCD display, max. 60000 dgt.
Displays the update rate 5 times/s (Capacitive coupling: based on measurement values 0.05~2 times/s, temperature: 1 time/s)
Power supply No. 5 alkaline battery (LR6) *4, continuous usage time: 100 hours
Volume and weight 93W * 197H * 53D mm, 650g (including battery and test cable)
Attachment

Test line L9207-10※2*1, user manual * 1, AA alkaline battery (LR6) *4

※2: Starting from March 2025, the L9300 will gradually replace the L9207-10.


Product Tags:

HIOKI digital multimeter high precision

      

DT4282 multimeter high-speed response

      

professional DMM testing equipment

      
Buy cheap HIOKI Digital Multimeters DT4281 And DT4282 Effectively Completed Professional Testing High Precision And High-speed Response product

HIOKI Digital Multimeters DT4281 And DT4282 Effectively Completed Professional Testing High Precision And High-speed Response Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Shaanxi Qindiyuan Environmental Protection Equipment Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)